- Temperature measurement directly inside the sample
- Accurate, homogeneous water bath temperature control
- Large selection of temperature-controlled measurement tubes
- Quick coupling system for an easy measurement tube change
- Highest accuracy over the entire measurement range
- Very short measurement time of approx. 1 s
- Measurement up to an optical density of 3.0 OD
Showing 1 - 2 out of 2
Page 1 out of 1
Product Name and Short Description | Thumbnails | SKU | Quantity | Total Price | Action | |
---|---|---|---|---|---|---|
Automatic Polarimeter: Measuring ranges: +/-90°; 259 °Z Accuracy: +/-0.003°; 0.01 °Z
|
![]() |
P8000-T
|
|
|
$13,439.00 |
|
Automatic Polarimeter: Measuring ranges: +/-90°; 259 °Z Accuracy: +/-0.002°; 0.01 °Z
|
![]() |
P8100-T
|
|
|
$16,691.00 |
Features
The polarimeter models P8000-T and P8100-T will allow for a circulation thermostat temperature control in the range between 8 °C and 40 °C when combined with temperature controlled measurement tubes and a thermostat. That makes them suitable for high-precision measurements in quality control. Especially if a multitude of different temperature controlled measurement tubes are to be used, the P8000-T and P8100-T are the right choice. We offer a very large selection of this type of tubes.
- Temperature measurement directly inside the sample
- Accurate, homogeneous water bath temperature control
- Large selection of temperature-controlled measurement tubes
- Quick coupling system for an easy measurement tube change
- Highest accuracy over the entire measurement range
- Very short measurement time of approx. 1 s
- Measurement up to an optical density of 3.0 OD
- Intuitive operation via touch-screen display
- Predefined scales (opt. rotation, spec. rotation, int. sugar scale, concentration)
- Any number of freely definable scales with conversions based on tables or formulas
- Chemical-resistant materials
- Compliance with GMP/GLP, 21 CFR Part 11, Pharmacopeia (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST
P8000-T | P8100-T | |
---|---|---|
MEASUREMENT DATA | ||
SCALES | Optical rotation [°]
Int. sugar scale [°Z]
Concentration [g/100 ml]
Spec. rotation User-defined |
|
MEASUREMENT RANGE | ±90° ±259 °Z |
|
MEASUREMENT ACCURACY | ±0.003° ±0.01 °Z |
±0.002° ±0.01 °Z |
RESOLUTION | 0.001° 0.01 °Z |
|
MEASUREMENT PERIOD ±90° | Approx. 1 s | |
LIGHT SOURCE | 1 LED with filter | |
WAVELENGTH | 589 nm | |
TEMPERATURE DATA | ||
TEMPERATURE CONTROL | With Circulation Thermostat PT31/PT80 and temperature-controlled measurement tube | |
TEMPERATURE CONTROL RANGE | 5–80 °C | |
TEMPERATURE CONTROL ACCURACY | ±0.2 °C | |
TEMPERATURE MEASUREMENT | With temperature probe PRT-E or PRT-T | |
TEMPERATURE MEASUREMENT RANGE | 0–99.9 °C | |
TEMPERATURE MEASUREMENT RESOLUTION | 0.1 °C | |
TEMPERATURE MEASUREMENT ACCURACY | ±0.2 °C |